20% OFF shipping at www.letsgoget.info on orders over $79 + up to 10% OFF products
www.letsgoget.info
home > Forté Zephair ZA1 Gentle Air Mattress System > Forté Zephair ZA1 Gentle Air Mattress System
download picture
Forté Zephair ZA1 Gentle Air Mattress SystemDUAL THERAPY STATIC IMMERSION & ACTIVE AIR ALTERNATION The globally recognised indication of a support surfaces effectiveness in pressure injury (PI) prevention has been through its ability to either reduce the peak strain stress values in tissues to constant low pressure (CLP) such as a pressure redistribution support surfaces (Refer to High Care Mattress Range) or by decreasing the continuous exposure time of tissues to the sustained strain stress
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

DUAL THERAPY – STATIC IMMERSION & ACTIVE AIR ALTERNATION

The globally recognised indication of a support surface’s effectiveness in pressure injury (PI) prevention has been through its ability to either reduce the peak strain/stress values in tissues to constant low pressure (CLP) such as a pressure redistribution support surfaces (Refer to High Care Mattress Range) or by decreasing the continuous exposure time of tissues to the sustained strain/stress state such as by repositioning or alternating air support surface. Advances in the technology of support surfaces are now moving toward a combination of both the aforementioned indicators of support surface effectiveness.

Support surfaces known as a ‘Hybrid’ are one such example of combining the technologies of CLP and AS through the use of both powered Air cells in conjunction with Foam configured wither as a layer of foam (either simple or castellated foam) at the patient interface (Known as‘ foam above cell’), or as powered air cells around the foam inserts, which effectively provides a layer of alternating air cells above the foam.

Debate amongst healthcare professionals also questions the efficacy of including CLP into an AS, where the question is asked, will there be sufficient offload to allow for the body’s natural blood flow and responsive measures in preventing pressure injuries such as reactive hyperaemia. Studies have shown that smaller pressure amplitudes, such as those seen with a Hybrid AS, generally provide sufficient pressure relief to maintain tissue viability, whereas when the pressure amplitudes are larger like the 100/0 traditional AS, then there is a tendency toward compromised tissue viability even in able-bodied subjects.

A 100/0 AS will provide such high peak pressures (even though there is a 100% offload) that the surface can provide more harm than good to a user. Moreover, studies into the speed of pressure injury have shown that the incidence of high pressures particularly against bony prominences can result in “massive apoptotic cell death within Minutes”.

REDUCING PEAK PRESSURES

The unique configuration of the Zephair incorporating static immersion and alternating therapy, also know as hybrid, is designed to reduce overall peak pressures across the patient interface of the support surface.

The major difference between a traditional AS and a Hybrid AS includes the amount of ‘offload’ achieved. For example, in a 1:2 alternating air system, for every cell ‘A’, 100% of the body’s mass is supported on 50% of the cells, with every second cell achieving full ‘offload’ to allow for blood flow and relief of pressure – A system known as 100-0 or ‘High Amplitude’ System. A hybrid system, in contrast, will not achieve the full offload, but will always have ‘pressure’ of some form on both the inflated and deflated cells, due to the nature of foam – its tendency to ‘spring back’ into position. A hybrid system may achieve an offloading result closer to 80-20 with 80 percent of the body supported on 50% of cells and 20% of the body supported on the remaining cells.

One such product utilising the advancement of hybrid technology is the Forté Healthcare Zephair Hybrid Powered Alternating Air Support Surface, operating with the FA configuration. The FA configuration stands out in the industry as a comfort-enhancing product, mainly due to the foam reducing or eliminating the feel of a ‘plastic-like’ air cell.

IS IT OK TO HAVE FOAM ON AIR CELLS?

Often postulated between health care professionals is the belief that for an alternating air pressure mattress to operate effectively, placing objects on the surface that may obstruct the movement of air between the cells must be avoided. The result of which means that FA surfaces such as the Zephair are overlooked due the foam being perceived as a ‘hindrance’ to clinical function and acting as a barrier between the air cells and the user.

The industry good practice statement is in fact referring to objects which do not provide pressure redistributing or pressure relieving properties. Medical continence care products such as a waterproof sheet or pad are the intention of the statement due to the mechanical nature of such products. Waterproof sheets, for example are often constructed from PVC/Vinyl, which as a rigid material, provides little to no stretch. A non-stretch material like PVC will prevent a user from sinking into the mattress and act much as a ‘hammock’, suspending the user ‘above’ the mattress rather than ‘in’ the mattress, thus presenting the industry statement is indeed a relevant and worthy consideration.

However, in the case of a FA hybrid mattress such as the Zephair, foam is a pressure redistributing substance, allowing for deflection and stretch around bony prominences. The foam used above the cells acts to provide more comfort to the user through two forms:

1) Reducing the ‘amplitude’ between inflated and deflated cells

2) Creating a more plush surface

IMPORTANCE OF PATIENT COMPLIANCE FOR HIGH RISK INDIVIDUALS

Comfort = Compliance

When pain is relieved by the support surface:

a. The individual is more sensitive to discomfort and pain which may indicate concentrated pressure – a warning sign that there is a risk of pressure injury formation

b. Better sleep = less fatigue = more stamina = better physical and mental endurance for client and caregivers

c. Reduces need for pain and sleep medication – improves cognitive state, less strenuous care regimens

Sizes and Availability

ZAS1000 - Stocked - Single

ZASL1000 - Stocked - Long Single

ZAKS1000 - Stocked - King Single

ZAKSL1000 - Stocked - Long King Single

ZAEW1000 - Made to Order - Extra Wide

ZAEWL1000 - Made to Order - Long Extra Wide

ZAD1000 - Made to Order - Double

ZADL1000 - Made to Order - Long Double

ZAQ1000 - Made to Order - Queen

ZAQL1000 - Made to Order - Long Queen

ZAK1000 - Made to Order - King

ZAKL1000 - Made to Order - Long King

ZASQ1000 - Made to Order - Split Queen

ZASQL1000 - Made to Order - Long Split Queen

 

Forté Zephair ZA1 Gentle Air Mattress System

Item no : 97272156911
sold recently : Login >>
US$ 2059.00
Pay in 4 interest-free payments of $514.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 21 - Jun 26

Enjoy 20% off shipping

US$ 2059.00

1-11

US$ 1853.10

12-35

US$ 1441.30

36-59

US$ 1235.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches